ABB Ltd
ABB DSE201MC40A30 DSE201MC40A30 RCBO
DSE201 M is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) in one module for the protection against short-circuit currents, overload, earth fault currents, indirect contacts, additional protection against direct contacts (30 mA versions). DSE201 M is equipped with supply neutral wire and functional earth wire.
Specifications
| Part number | DSE201MC40A30 |
|---|---|
| Brand | ABB Ltd |
| Category | Residual current breakers (RCBO) |
| Standards | IEC 61009-1 IEC 61009-2-2 BS EN 61009-1 AS/NZS 61009 |
| Power Loss | 5.5 W |
| Housing Type | Insulation group II, RAL 7035 |
| Actuator Type | Toggle – Insulation group II, black, sealable in ON-OFF positions |
| Mounting Type | on DIN rail EN 60715 (35 mm) by means of fast clip device in consumer unit Type A according to IEC 61439-1&3, BS EN 61439-1&3, in distribution board Type B according to IEC 61439-1&3, BS EN 61439-1&3. |
| Terminal Type | Screw Terminals |
| Accessory Type | Auxiliary contact Signal contact / auxiliary contact Shunt trip Undervoltage release Overvoltage release Auxiliary contact for MCBs bottom fitting |
| Number of Poles | 1+N |
| Fault Indication | Blue window |
| Pollution Degree | 2 |
| Test Voltage (Ut) | 195 … 264 V |
| Tightening Torque | Top 1.2 N·m Bottom 2.8 N·m |
| Caractéristique 1 | Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 15 kA |
| Caractéristique 2 | Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA |
| Caractéristique 3 | Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms |
| Caractéristique 4 | Resistance to Vibrations acc. to IEC 60068-2-6: 0.35mm or 5g – 20 cycles at 5…150…5 Hz without load |
| Connecting Capacity | Busbar 10 mm² Rigid 35 …35 mm² Flexible 25 …25 mm² |
| Rated Frequency (f) | 50…60 Hz |
| Screw Terminal Type | Cage Terminal |
| Degree of Protection | Housing IP40 Terminals IP20 |
| Electrical Endurance | 10000 cycle |
| Overvoltage Category | III |
| Rated Current (I n ) | 40 A |
| Rated Voltage (U r ) | 230-240 V AC |
| Energy Limiting Class | 3 |
| Rated Residual Current | 30 mA |
| Dielectric Test Voltage | 2.5 kV |
| Power Supply Connection | Bottom |
| Tripping Characteristic | C |
| Environmental Conditions | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % |
| Type of Residual Current | A type |
| Number of Protected Poles | 1 |
| Contact Position Indication | Red ON / Green OFF |
| Position of Neutral Terminals | Right |
| Mechanical Endurance (N endu ) | 20000 cycle |
| Rated Insulation Voltage (U i ) | 500 V |
| Reference Ambient Air Temperature | 30 °C |
| Rated Short-Circuit Capacity (I cn ) | 10 kA |
| Primary Rated Impulse Withstand Voltage | 4 kV |
| Rated Residual Breaking Capacity (IΔm) | 10 kA |
Prices are reserved for our customers. Sign in or request a quote to get pricing and place an order.