Engcore Ltd — Expertise and reliability
ABB DSE201MC40A30 DSE201MC40A30 RCBO
ABB Ltd

ABB DSE201MC40A30 DSE201MC40A30 RCBO

DSE201 M is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) in one module for the protection against short-circuit currents, overload, earth fault currents, indirect contacts, additional protection against direct contacts (30 mA versions). DSE201 M is equipped with supply neutral wire and functional earth wire.

Specifications

Part numberDSE201MC40A30
BrandABB Ltd
CategoryResidual current breakers (RCBO)
StandardsIEC 61009-1 IEC 61009-2-2 BS EN 61009-1 AS/NZS 61009
Power Loss5.5 W
Housing TypeInsulation group II, RAL 7035
Actuator TypeToggle – Insulation group II, black, sealable in ON-OFF positions
Mounting Typeon DIN rail EN 60715 (35 mm) by means of fast clip device in consumer unit Type A according to IEC 61439-1&3, BS EN 61439-1&3, in distribution board Type B according to IEC 61439-1&3, BS EN 61439-1&3.
Terminal TypeScrew Terminals
Accessory TypeAuxiliary contact Signal contact / auxiliary contact Shunt trip Undervoltage release Overvoltage release Auxiliary contact for MCBs bottom fitting
Number of Poles1+N
Fault IndicationBlue window
Pollution Degree2
Test Voltage (Ut)195 … 264 V
Tightening TorqueTop 1.2 N·m Bottom 2.8 N·m
Caractéristique 1Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 15 kA
Caractéristique 2Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA
Caractéristique 3Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms
Caractéristique 4Resistance to Vibrations acc. to IEC 60068-2-6: 0.35mm or 5g – 20 cycles at 5…150…5 Hz without load
Connecting CapacityBusbar 10 mm² Rigid 35 …35 mm² Flexible 25 …25 mm²
Rated Frequency (f)50…60 Hz
Screw Terminal TypeCage Terminal
Degree of ProtectionHousing IP40 Terminals IP20
Electrical Endurance10000 cycle
Overvoltage CategoryIII
Rated Current (I n )40 A
Rated Voltage (U r )230-240 V AC
Energy Limiting Class3
Rated Residual Current30 mA
Dielectric Test Voltage2.5 kV
Power Supply ConnectionBottom
Tripping CharacteristicC
Environmental Conditions28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Type of Residual CurrentA type
Number of Protected Poles1
Contact Position IndicationRed ON / Green OFF
Position of Neutral TerminalsRight
Mechanical Endurance (N endu )20000 cycle
Rated Insulation Voltage (U i )500 V
Reference Ambient Air Temperature30 °C
Rated Short-Circuit Capacity (I cn )10 kA
Primary Rated Impulse Withstand Voltage4 kV
Rated Residual Breaking Capacity (IΔm)10 kA